home Industrial & Commercial Scales - ScalesGalore
home Industrial & Commercial Scales - ScalesGalore

Mettler Toledo InLab® Sensors Electrodes

The manufacturing of high quality sensors with outstanding performance not only requires technical skills and expertise but also a profound understanding of the various customer applications and their specific requirements. METTLER TOLEDO has built up an enormous treasure trove of experience and knowledge over the last decades, which has resulted in a complete sensor portfolio that supports any of your applications Mettler Toledo pH Meters


Mettler Toledo InLab® Sensors Electrodes
Have Questions?
Call USoremail Us
Our Staff will be glad to help
Mettler Toledo InLab® Sensors Electrodes

Calibration and Cleaning Solutions

General Purpose pH Glass

Premium pH Glass Electrodes

Specialist Micro pH Glass Electrodes

Specialist Solid pH Glass Electrodes

Specialist Low Temperatures pH Glass Electrodes

ORP Electrodes

Conductivity Electrodes

Sensors for Mobile Applications

Combined Ion-Selective Electrodes

Performance to Trust
Measurements have to be fast, precise and reproducible. Tried and trusted technologies combined with state-of-the-art production processes guarantee highest performance for every InLab sensor, providing reliable results at any time.

Easy to Use
All InLab sensors are shipped ready to use. Everything you need for your measurement comes together with the sensor. Your work in the lab will be simplified by application specific sensors, automatic recognition of ISM sensors and the spillfree wetting cap

Built to Last
The thought-out InLab sensor construction as well as the highquality materials used for manufacturing guarantee high robustness even in harsh applications. The versatile sensor portfolio ensures the perfectly suited sensor for every application, a match that greatly extends the lifetime of the products.

InLab® Sensor Technology Proven Reliability
The variety of electrochemical sensors is as diverse as the applications they are used for. Only the right combination of high-quality materials, tried-and-trusted technologies, and the shape of the membrane make a sensor perfectly suited for a specific application.

  • Membrane Glass - The membrane is the pH sensing part of the sensor. Its shape and glass composition are optimized to assure best results for different applications.
  • HA – High alkali glass with low alkali error for high pH values and high temperatures.
  • U – Universal glass for standard applications and small membranes.
  • A41 – highly robust glass particularly resistant to harsh chemicals, suitable for high temperatures.
  • LoT – Low temperature glass with low resistance. Suitable for samples with low temperatures and low ion concentrations.
  • HF – Hydrofluoric acid resistant glass for samples containing hydrofluoric acid (up to 1 g/L).

  • Wetting Cap - Ready to use at any time, easy to handle and spill proof. Perfect to keep the glass membrane hydrated.
  • Junction - The junction is the connection between the reference electrolyte and the sample.
  • Temperature Probe - Temperature compensation included! The pH value of a solution is temperature dependent. Thus, the temperature should be measured with every pH value.
  • Ceramic Junctions - For general applications.
  • Sleeve Junctions - For fast results, best in dirty samples.
  • Open Junctions - For easy cleaning and clogfree measurement.
  • SafeLock™ - For refillable sensors: easy to open for measurement, perfectly sealed for storage and transport.
  • Reference Electrolyte - Liquid electrolytes are typically used for general applications and provide fast results. Polymer or gel electrolytes stand for low maintenance.
  • Shaft Material - The sensor robustness is dependent on the right shaft material. Glass is highly chemically resistant and allows for measurements at high temeratures. When mechanical robustness is key, plastic is the preferred material
  • Reference System - Provides a stable potential against which the pH dependent potential can be compared.
  • ARGENTHAL™ with silver ion trap - For silver ion free electrolyte. No clogging of the junction due to sulfide or protein containing samples or TRIS buffers.
  • SteadyForce™ - Pressurized (3 bar) electrolyte ensures electrolyte flow even in viscous samples and guarantees highly reproducible results.

ISM

  • Intelligent Sensor Management - Every ISM marked sensor offers data security and easy handling.
  • Secure and efficient - Calibration data and sensor ID are automatically transferred to the meter.
  • Always up to date - New calibration data are stored in the sensor.
  • Backup certificate guaranteed - Initial factory calibration is stored in the sensor.
  • Conclusive calibration history - The last five calibrations are stored in the sensor.
  • Easy lifetime monitoring - The maximum temperature that the sensor has been exposed to is monitored automatically.

General Purpose pH Glass Electrodes

Time is Precious Sensors for Fast Results

Liquid filled electrodes are reliable workhorses, constructed for efficient pH measurements in daily laboratory use of a wide application range. For more complex sample matrices like emulsions or biological media, electrodes with a sleeve junction are recommended.

Electroplating is a common technique used to coat metals in order to add desired properties to them. Strong acids and bases are needed for this process and the robust HA glass of the InLab Routine Pro-ISM is ideal for this application as it covers the whole pH range with an extremely low alkali error.

Model Mono
51343195
LE 407
51340330
LE 409
51340331
LE 420
51340332
LE 422
30089747
LE 428
51340242
Price Mettler Toledo® InLab® 51343195pH Half-Cell Mono Electrode
$223.52
Mettler Toledo® 51340330 pH Sensor LE 407
$149.96
Mettler Toledo® InLab® 51340331 pH Sensor LE 409
$170.28
Mettler Toledo®  51340332 pH Sensor LE 420
$249.92
Mettler Toledo®  30089747 pH Sensor LE 422
$231.44
Mettler Toledo®  51340242 pH Sensor LE 438
$237.60
Measuring range pH 0 – 14 pH 0 – 14 pH 0 – 14 pH 0 – 14 pH 0 – 14 pH 0 – 14
Temperature Range 0 oC , 100 oC 0 oC , 80 oC 0 oC , 80 oC 0 oC , 80 oC 0 oC , 80 oC 0 oC , 80 oC
Shaft Material Membrane glass HA POM Glass Glass Glass POM
Type of junction - Polyster Ceramic Movable PTFE sleeve Ceramic Polyster
Membrane resistance (25 oC) < 600 MΩ < 250 MΩ < 600 MΩ < 600 MΩ < 250 MΩ < 250 MΩ
Sensor Type Half-cell Combined electrode Combined electrode Combined electrode Combined electrode Combined electrode
Shaft length 120 mm 120 mm 120 mm 120 mm 90 mm 120 mm
Shaft Diameter 12 mm 12 mm 12 mm 12 mm 4.3 mm 12 mm
Signal type Analog Analog Analog Analog Analog Analog
Connector on Sensor S7 Fixed 1 m cable Fixed 1 m cable Fixed 1 m cable Fixed 1 m cable Fixed 1 m cable
Connector to Meter Flexible (detachable cable) BNC BNC BNC BNC BNC/RCA (Cinch)
Minimum Sample Volume uL 20 mL 20 mL 20 mL 20 mL 100 µL 20 mL
Sample Composition Aqueous Aqueous High salt content (aqueous) Aqueous,Contains proteins / TRIS / sulfides (aqueous),High salt content (aqueous) - Aqueous
Sample Consistency Liquid,Sludge / slurry / suspension Liquid Liquid Viscous,Emulsion Contains proteins / TRIS / sulfides (aqueous) Liquid,Sludge / slurry / suspension
Sensor Characteristics Chemically robust Liquid,Sludge / slurry / suspension Chemically robust Chemically robust Chemically robust,Small volume Temperature Probe,Mechanically robust
Typical Samples Water,Beer, Suspended soil Water,Beer, Suspended soil Sea Water,Brine Cosmetic lotions,Shower gel TRIS buffers,Enzyme solution,Proteinaceous samples Water,Beer, Suspended soil
Customs tariff number 9027905695
Sensor Characteristics: IP67,Mechanically robust, Sample General Purpose,water Sample General Purpose,water Sample:Waste water, emulsions, Reference System:Ag/AgCl, Reference electrolyte: 3 mol/L KCl Sample Volume: 100 µL - 500 µL, Sample: Small samples, Reference System: Ag/AgCl, Country of origin: GB Sample General Purpose,water, Reference System: Ag/AgCl, Reference electrolyte: Gel, Temperature Probe: NTC 30 kO


Model Routine
51343050
Routine Pro
51343054
Routine Pro-ISM
51344055
Science
51343070
Science Pro-ISM
51344072
Versatile Pro
51343031
Price Mettler Toledo® InLab® Routine 51343050 General Purpose 2-in-1 ARGENTHAL with Ag+ ion trap Electrode
$264.88
Mettler Toledo® InLab® Routine 51343054 General Purpose 3-in-1 ATC probe (TRIS compatible) Electrode
$388.96
Mettler Toledo® InLab® Routine 51344055 4-in-1 General Purpose ATC Probe with Argenthal with ISM Electrode
$462.00
Mettler Toledo® InLab® Routine 51343070 4-in-1General Purpose 2-in-1 Movable glass sleeve Electrode
$453.20
Mettler Toledo® InLab® Routine 51344072 4-in-1 General Purpose ATC Probe with moveable glass sleeve and ATC Electrode
$717.20
Mettler Toledo® InLab® Routine 51343031 Economy 3-in-1 Replaceable junction, refillable, ATC probe Electrode
$332.64
pH range 0 – 14 0 – 14 0 – 14 0 – 12 0 – 12 0 – 14
Temperature probe - NTC 30 kΩ NTC 30 kΩ - NTC 30 kΩ NTC 30 kΩ
Type of membrane glass HA HA HA A41 A41 U
Membrane resistance (25 oC) < 600 MΩ < 600 MΩ < 600 MΩ < 600 MΩ < 600 MΩ < 250 MΩ
Type of junction Ceramic Ceramic Ceramic Movable glass sleeve Movable glass sleeve Ceramic
Bridge electrolyte - - - - 3 mol/L KCl -
Cable and connection S7 MultiPin™ MultiPin™ S7 MultiPin™ 1.2 m cable; BNC / RCA
Shaft material Glass Glass Glass Glass Glass Polysulfone
Shaft length 120 mm 120 mm 120 mm 120 mm 170 mm 120 mm
Common specifications Type of electrode: pH-combination / Reference system: ARGENTHAL™ with Ag+-trap / Reference electrolyte: 3 mol/L KCl Temperature range: 0…100 oC / Shaft diameter: 12 mm



Premium pH Glass Electrodes

Always Ready Maintenance-Free Sensors

Well-equipped for challenging tasks. The highly robust PEEK shaft in combination with the open junction makes the InLab Expert both resilient and easy to handle. Its solid reference electrolyte requires no refilling and is always ready for use. If highest performance is expected, the InLab Power is the first choice.

The InLab Power-Pro-ISM is simply brilliant. The SteadyForce™ reference system is under over-pressure. This guarantees highest reproducibility of pH measurements even in challenging samples like polymeric dispersions which are used in the production of plastics.

Model Expert Pro
51343101
Expert Pro-ISM
30014096
InLab® Power
51343110
Power Pro-ISM
51344211
Easy
51343010
Reference
51343190
Price Mettler Toledo® InLab® Expert Pro 51343101 Premium 3-in-1 Open junction, PEEK shaft, 0 to 100°C Electrode
$404.80
Mettler Toledo® IInLab® Expert Pro ISM 30014096 Premium 4-in-1 Open junction, PEEK shaft, 0 to 100°C with Intelligent Sensor Management Electrode
$484.00
Mettler Toledo® InLab® Power 51343110 Premium 2-in-1 Pressurized reference system SteadyForce™ Electrode
$712.80
Mettler Toledo® InLab® Power 51344211 Premium 4-in-1 Pressurized reference system SteadyForce, ATC with ISM Electrode
$887.40
Mettler Toledo® InLab® Power 51343010  Economy 2-in-1 Gel-filled, polysulfone shaft Electrode
$232.32
Mettler Toledo® InLab® 51343190 pH Half-Cell Reference Electrode
$218.24
pH range 0 – 14 0 – 14 0 – 12 0 – 12 0 – 14 -
Temperature range 0 to 100 oC 0 to 100 oC 0 to 130 oC 0 to 130 oC 0 to 80 oC 0 to 100 oC
Temperature probe - NTC 30 kΩ - NTC 30 kΩ - -
Type of membrane glass U U A41 A41 U -
Membrane resistance (25oC) < 250 MΩ < 250 MΩ < 600 MΩ < 600 MΩ < 250 MΩ -
Type of junction Open junctions Open junctions Ceramic Ceramic Ceramic Ceramic
Reference system ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap SteadyForce™ SteadyForce™ ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap
Reference electrolyte XEROLYT® Polymer XEROLYT® Polymer DPA-Gel DPA-Gel Gel 3 mol/L KCl
Cable and connection S7 1.2 m cable; BNC / RCA (Cinch) S7 MultiPin™ S7 S7
Shaft material PEEK PEEK Glass Glass Polysulfone Glass
Shaft length 120 mm 120 mm 120 mm 170 mm 120 mm 120 mm
Shaft diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm
InLab® Expert NTC30 The InLab® Expert Pro is also available with a MultiPin™ connector: Order number 51343104 -
InLab® Easy BNC The InLab® Easy is also available with a 1.2 m cable (BNC): Order number 51343011 -
Common specifications Type of electrode: pH-combination / Shaft diameter: 12 mm Sensor Characteristics:Chemically robust and Customs tariff number 9027905695



Specialist Micro pH Glass Electrodes

Nothing is Impossible Sensors for Small Volumes

The more precious or limited the sample, the greater the challenge to use it for analysis. The narrow sensor shaft of micro pH sensors fits in nearly every sample container and enables measurements of sample volumes down to the lower ìL ranges.

The InLab Ultra-Micro-ISM allows pH measurements of sample volumes down to 15 ìL. Key for any lab working with expensive or precious micro samples

Model Ultra-Micro-ISM
30244732
Micro
51343160
Micro Pro-ISM
51344163
Semi-Micro
51343165
Flex-Micro
51343164
Price
$528.00
Mettler Toledo® InLab® Micro 51343160 Specialist 2-in-1 3 mm shaft diameter Electrode
$410.96
Mettler Toledo® InLab® Micro Pro-ISM 51344163 Specialist 4-in-1 5 mm shaft diameter, with ATC and ISM Electrode
$739.20
Mettler Toledo® InLab® Semi-Micro 51343165 Specialist 2-in-1 6 mm shaft diameter Electrode
$410.96
Mettler Toledo® InLab® Flex-Micro 51343164 Specialist 2-in-1 Epoxy shaft Electrode
$616.00
pH range 1 - 11 0 – 14 0 – 14 0 – 12 0 – 14
Temperature range 0 to 80 oC 0 to 80 oC 0 to 100 oC 0 to 100 oC 0 to 80 oC
Temperature probe - - NTC 30 kΩ - -
Type of membrane glass LoT U U A41 U
Membrane resistance (25oC) < 700 MΩ < 1000 MΩ < 300 MΩ < 600 MΩ < 600 MΩ
Type of junction Ceramic Ceramic Ceramic Open junction Porous PTFE
Reference system ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap
Reference electrolyte FRISCOLYT-B® 3 mol/L KCl 3 mol/L KCl XEROLYT®EXTRA Polymer Gel
Cable and connection MultiPin™ S7 MultiPin™ S7 1.0 m cable; BNC
Shaft material Glass Glass Glass Glass Epoxy
Shaft length 40 mm 60 mm 130 mm 100 mm 180 mm
Shaft diameter 3 mm 3 mm 5 mm 6 mm 6 mm
Shaft diameter 15 µL 45 µL 100 µL 100 µL 500 µL
Common specifications Type of electrode: pH-combination



Specialist Solid pH Glass Electrodes

Accept the Challenge Sensors for Solid and Viscous Samples

The measurement of solid or semi-solid samples is challenging and requires sensors that are robust, ensure proper electrolyte flow and are easy to clean. Sensors with these properties are often requested for food or cosmetic applications.

The pH value is an indicator for the ripeness of fruits. Thanks to the puncture electrode InLab Solids it is possible to measure where it counts: directly in the fruit. Strawberries taste best at a pH of 3.5.

Model Solids
51343153
Solids Pro-ISM
51344155
Viscous
51343150
Viscous Pro-ISM
51343151
Surface
51343157
Surface Pro-ISM
30249570
Price Mettler Toledo® InLab® Solids 51343153 Specialist 2-in-1 Spear tip Electrode
$470.80
Mettler Toledo® InLab® Solids Pro-ISM 51344155 Specialist 4-in-1 Spear tip, ATC probe with ISM Electrode
$572.00
Mettler Toledo® InLab® Viscous 51343150 Specialist 2-in-1 SteadyForce™, special thin tip Electrode
$739.20
Mettler Toledo® InLab® Viscous Pro ISM 51343151 Specialist 4-in-1 SteadyForce™, specialized thin tip, ATC with ISM Electrode
$904.80
Mettler Toledo® InLab® Surface 51343157 Specialist 2-in-1 SteadyForce™, special thin tip Electrode
$385.44
Mettler Toledo® InLab® Surface Pro-ISM 30249570 Specialist 4-in-1 SteadyForce™, specialized thin tip, ATC with ISM Electrode
$558.80
pH range 1 - 11 1 - 11 0 – 14 0 – 14 1 - 11 1 - 11
Temperature range 0 to 80 oC 0 to 80 oC 0 to 130 oC 0 to 130 oC 0 to 50 oC 0 to 50 oC
Temperature probe - NTC 30 kΩ - NTC 30 kΩ - NTC 30 kΩ
Type of membrane glass LoT LoT HA HA LoT LoT
Membrane resistance (25oC) < 250 MΩ < 250 MΩ < 600 MΩ < 600 MΩ < 800 MΩ < 800 MΩ
Type of junction Open junction Open junction Ceramic Ceramic Ceramic ring Ceramic ring
Reference system ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap SteadyForce™ SteadyForce™ ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap
Reference electrolyte XEROLYT®EXTRA Polymer XEROLYT®EXTRA Polymer FRYSCOLYT-C® FRYSCOLYT-C® 3 mol/L KCl 3 mol/L KCl
Cable and connection S7 MultiPin™ S7 MultiPin™ S7 MultiPin™
Shaft length 25 mm 25 mm 40 mm 40 mm 120 mm 120 mm
Shaft length 6 mm 6 mm 6 mm 6 mm 12 mm 12 mm
Common specifications Type of electrode: pH-combination / Shaft material: Glass



Specialist Low Temperatures pH Glass Electrodes

Pure Performance Low Temperatures and Ionic Strenght

A special membrane glass and a large membrane surface are typical characteristics for sensors suited for measuring in samples at low temperatures or with low ion concentrations. One of the key areas of application is the measurement of pure water at various levels of purity.

Pure water is a key ingredient in every pharmaceutical production process. The InLab Pure Pro-ISM convinces with a strong performance in weak ionic strength samples.



Reach New Depths Long Sensors

The deeper the container, the more difficult it gets to reach the sample. Sensors with especially long and robust shafts are required for proper pH measurements in very deep or narrow containers

From the chalk board to experimental reactions to ultimately the final formulation. The extra-long InLab Reach sensors are a solid companion during the whole scale-up process in the pilot production

Model Pure
30248112
Pure Pro-ISM
51344172
Cool
51343174
Cool Pro-ISM
30247850
Hydrofluoric
51343176
Reach Pro-425
51343061
Water Go
30253098
Price Mettler Toledo® InLab® Pure 30248112 Specialist 2-in-1 For use in pure water or low ionic strength solutions  Electrode
$506.00
Mettler Toledo® InLab® Pure Pro-ISM 51344172 Specialist 4-in-1 For use in pure water or low ionic strength solutions, with ATC and ISM  Electrode
$695.20
Mettler Toledo® InLab® Cool 51343174 Specialist 2-in-1 FRISCOLYT-B electrolyte, –30 to 80°C  Electrode
$506.00
Mettler Toledo® InLab® Cool Pro-ISM 30247850 Specialist 4-in-1 For low temperature measurement, with ATC and ISM  Electrode
$616.00
Mettler Toledo® InLab® Hydrofluoric 51343176 Specialist 2-in-1 Special HF resistant membrane  Electrode
$558.80
Mettler Toledo® InLab® Reach Pro-425 Pro-ISM 51343061 Specialist 4-in-1 For low temperature measurement, with ATC and ISM  Electrode
$646.80
Mettler Toledo® InLab® 30253098 Water Go Electrode
$541.20
pH range 1 - 11 1 - 11 1 - 11 1 - 11 1 - 11 1 - 14 1 - 11
Temperature range 0 to 80 oC 0 to 80 oC -30 to 80 oC -30 to 80 oC 0 to 100 oC 0 to 100 oC 0 to 80 oC
Temperature probe - NTC 30 kΩ - NTC 30 kΩ - NTC 30 kΩ NTC 30 kΩ
Type of membrane glass LoT LoT LoT LoT HF HA LoT
Membrane resistance (25oC) < 50 MΩ < 50 MΩ < 50 MΩ < 50 MΩ < 100 MΩ < 600 MΩ < 150 MΩ
Type of junction Immovable glass sleeve Immovable glass sleeve Immovable glass sleeve Immovable glass sleeve Ceramic Ceramic Porous PTFE
Reference electrolyte FRYSCOLYT-B® 3 mol/L KCl FRYSCOLYT-B® FRYSCOLYT-B® 3 mol/L KCl 3 mol/L KCl 3 mol/L KCl
Bridge electrolyte - 1 mol/L KCl - - - - -
Cable and connection S7 MultiPin™ S7 MultiPin™ S7 MultiPin™ 1.8 m BNC (IP67)/RCA (Cinch)
Shaft material Glass Glass Glass Glass Glass Glass Polysulfone
Shaft length 120 mm 170 mm 120 mm 120 mm 120 mm 425 mm 120 mm
Common specifications Type of electrode: pH-combination / Reference system: ARGENTHAL™ with Ag+-trap / Shaft diameter: 12 mm


ORP Electrodes

High Potential ORP Electrodes

Sensors that measure ORP (oxidation reduction potential) have to cope with similar challenges as pH sensors. Thus, the correct combination of reference system, junction, and shape are of equal importance for successful ORP measurements.

Fluffy bread with a crispy crust requires a well-controlled baking process. The InLab Redox allows bakeries to control the fermentation process of dough in an easy and efficient way.

Model InLab® Redox
51343200
InLab® Redox Flow
51343201
Redox Au
51343204
Redox Ag
51343205
Price Mettler Toledo® InLab® Redox 51343200 ORP electrode Platinum Ring
$395.12
Mettler Toledo® InLab® Redox Flow 51343201 ORP electrode Platinum Ring and movable glass junction
$607.20
Mettler Toledo® InLab® Redox Au 51343204 ORP Electrode Gold Ring
$541.20
Mettler Toledo® InLab® Redox Au 51343205 ORP Electrode Platinum Ring
$426.80
Type of electrode Combined ORP Combined ORP Combined ORP Combined ORP
Temperature range 0 to 100 oC 0 to 100 oC 0 to 100 oC 0 to 100 oC
Type of junction Ceramic Moveable glass sleeve Ceramic Ceramic
Reference electrolyte 3 mol/L KCl 3 mol/L KCl 3 mol/L KCl 3 mol/L KNO3
Shaft length 120 mm 120 mm 120 mm 120 mm
Shaft diameter 12 mm 12 mm 12 mm 12 mm
Metal Platinum ring Platinum ring Gold ring Silver ring
Storage 3 mol/L KCl 3 mol/L KCl 3 mol/L KCl 3 mol/L KNO3
Cable and connection S7 S7 S7 S7
Reference system ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap ARGENTHAL™ with Ag+-trap


Ions in Motion Conductivity Probes

InLab conductivity probes with 2-pole cells provide the highest accuracy at low conductivity levels. Probes with 4-pole cells display a great linearity over a large conductivity range and are best suited for samples with mid to high conductivity.

Ultrapure water is extensively used for the production of microelectronics and semiconductors. Its purity must be guaranteed and regularly checked. This is exactly the application for which the InLab 741-ISM was made for.

  • ISM® - Intelligent Sensor Management - All the important information is stored in the sensor and transferred automatically to the meter. An ideal support for fast and safe results
  • Always the right temperature - The integrated temperature probe guarantees you always measure with the right temperature compensation.

A 4 graphite poles conductivity cell with integrated temperature probe and ISM. Designed for general applications like standard and high conductivity samples.

Wide measuring range The 4-pole cell eliminates polarization effects and guarantees a great linearity over a huge conductivity range.

ISM® - Intelligent Sensor Management

All the important information is stored in the sensor and transferred automatically to the meter. An ideal support for fast and safe results.

Always the right temperature The integrated temperature probe guarantees you always measure with the right temperature compensation.

Model 731-ISM
30014092
741-ISM
30014094
710
51302256
717
51302401
720
51302255
751-4mm
51344030
752-6mm
51344031
Price Mettler Toledo® InLab® 731-ISM  30014092 Conductivity Probe
$611.60
Mettler Toledo® InLab® 741-ISM  30014094 Conductivity Probe
$866.80
Mettler Toledo® InLab® 710  51302256 Conductivity Probe  with 4 platinum poles
$484.00
Mettler Toledo® InLab® 717 51302401 Conductivity Probe  with 4 platinum poles
$484.00
Mettler Toledo® InLab®  720  Conductivity Probe  wit 2 Platinum Poles
$479.60
Mettler Toledo® InLab®  751-4mm 51344030  Conductivity Probe  wit 2 Platinum Poles
$904.80
Mettler Toledo® InLab®  752-6mm 51344031  Conductivity Probe  wit 2 Platinum Poles
$836.00
non-ISM version 731
51344020
741
51344024
- - - - -
Price $558.80
$836.00
- - - - -
Measuring range 0.01 to 1000
mS/cm
0.001 to 500
µS/cm
0.01 to 500
mS/cm
0.01 to 500
mS/cm
0.1 to 500
µS/cm
0.01 to 100
mS/cm
0.01 to 112
mS/cm
Temperature range 0 to 100 oC 0 to 100 oC 0 to 100 oC 0 to 100 oC 0 to 100 oC 0 to 100 oC 0 to 100 oC
Temperature probe NTC 30 kω NTC 30 kω NTC 30 kω NTC 30 kω NTC 30 kω NTC 30 kω NTC 30 kω
Cable and connection 1.2 m cable
Mini-DIN
1.2 m cable
Mini-DIN
1.2 m cable
Mini-DIN
1.2 m cable
Mini-DIN
1.2 m cable
Mini-DIN
1.2 m cable
Mini-DIN
1.2 m cable
Mini-DIN
Shaft material Epoxy Stainless steel Glass Epoxy Glass Glass Glass
Shaft length 120 mm 120 mm 120 mm 120 mm 120 mm 120 mm 180 mm
Shaft diameter 12 mm 12 mm 12 mm 12 mm 12 mm 4 mm 6 mm
Cell constant 0.57 cm 0.105 cm 0.80 cm - 0.06 cm 1.0 cm 1.0 cm
Cell type 4 graphite poles 2 steel poles 4 platinum poles 4 platinum poles 2 platinum poles 2 platinum poles 2 platinum poles
Compatible Meters S230/S700/S470/S475
Common specifications Type of electrode: Conductivity cell / Storage: dry


Sensors for Mobile Applications

Everywhere you Measure Sensors for Mobile Applications
Portable meters are often used in harsh environments, such as in near-process or outdoor areas. Sensors for mobile use have to be robust and IP67 waterproof, and are, thus, equipped with fixed cables.

Well-equipped for challenging tasks. The highly robust PEEK shaft in combination with the open junction makes the InLab Expert both resilient and easy to handle. Its solid reference electrolyte requires no refilling and is always ready for use. If highest performance is expected, the InLab Power is the first choice.

Maintenance-Free pH Sensors for the toughest conditions PEEK shaft with excellent chemical and mechanical resistance, a real heavy-duty sensor.

Reliability on the next level SteadyForce™ reference system is pressurized to prevent the junction from clogging, guaranteeing extremely reliable and reproducible results.

ISM® - Intelligent Sensor Management All the important information is stored in the sensor and transferred automatically to the meter. The ideal support for fast and safe results.

Always the right temperature The integrated temperature probe guarantees you always measure with the right temperature compensation.

The measuring of complex samples like suspended soil is child's play for the InLab Expert Go-ISM. Thanks to the open junction, there is nothing which can contaminate or falsify results.

pH Conductivity Dissolved oxygen
InLab® Model Expert Go-ISM Routine Go-ISM Solids Go-ISM 738-ISM 605-ISM OptiOx
ISM
w/1.8 m cable
51344102 30248832 51343156 - - 51344621
Price Mettler Toledo® InLab® 51344102 Expert Go-ISM  pH Electrode
$532.40
Mettler Toledo® InLab® 30248832 Routine Go-ISM  pH Electrode
$558.80
Mettler Toledo® InLab® 51343156 Solids Go-ISM  pH Electrode
$616.00
Mettler Toledo® InLab® 51344120 738 Conductivity Electrode (Not ISM)
Mettler Toledo® InLab® 51340291 605  Dissolved Oxygen Sensor (No ISM)
Mettler Toledo® InLab® 51344621 OptiOx Dissolved Oxygen Sensor
$1,313.70
non-ISM
w/1.8 m cable
51340288 - - 51344120 51340291 -
Price $479.60
- - $572.00
$1,078.80
-
Measuring range 0 to 14 pH 0 to 14 pH 1 to 11 pH 0.01 to 1000
mS/cm
0 to 200%
0 to 20 mg/L
0 to 500%
0 to 50 mg/L
Temperature range 0 to 100 oC 0 to 100 oC 0 to 80 oC 0 to 100 oC 0 to 60 oC 0 to 50 oC
Temperature probe NTC 30 kω NTC 30 kω NTC 30 kω NTC 30 kω NTC 22 kω NTC 30 kω
Membrane glass / detection U HA LoT - Polargraphic 1.2 m cable
Optical
Membrane resistance (25 oC) < 250 Mω < 250 Mω < 250 Mω - - -
Type of junction / Cell type Open junction Ceramic Open junction 4 graphite poles - -
Reference electrolyte XEROLYT Polymer 3 mol/L KCl XEROLYT EXTRA Polymer - - -
Cell constant - - - 0.57 cm - -
Shaft material PEEK Glass Glass Epoxy PPS PC / ABS
Shaft length 120 mm 120 mm 120 mm 25 mm 120 mm 65 mm
Shaft diameter 12 mm 12 mm 6 mm 12 mm 12 mm 16 mm
Storage InLab storage solution (not included) dry dry dry
Connections Fixed cable: BNC / RCA (Cinch) Fixed cable: LTW Fixed cable: BNC / RCA Fixed cable: Mini-LTW
Common specifications P67
Common specifications Type of electrode: Conductivity cell / Storage: dry

Combined Ion-Selective Electrodes

Catch Them All Combined Ion-Selective Electrode

As various as the range of different ions, as various is the selection of ion-selective electrodes (ISE). The special Click & Clear™ junction allows for an optimal contact of the electrolyte solution and the sample. With the dedicated solutions the sample can be optimally prepared for successful measurement of ion concentration

Quick cleaning and stable measurements The brilliant Click & Clear™ press mechanism allows for quick cleaning and ensures stable readings even in difficult samples

Complete solution Combined ion-selective electrodes have an integrated reference system. No additional reference electrode is needed.

Part # Measuring ion perfectION™ Cable and Connections Measuring Range Temperature Range Optimal pH Range Type of Membrane Reference Electrolyte Description Order no. ISA solution
51344700 Mettler Toledo® 51344700 Silver/Sulfide Combined Ion-selective electrode
$1,152.75
Ag+/S2- comb Ag+/S2 1.2 m; BNC 10-7 to 1 mol/L
Ag+ 0.01 to 108000 mg/L
S2- 0.003 to 32000 mg/L
0 to 80 oC 2 to 12 Solid State Ion Electrolyte B Silver/Sulfide Ag+ 51344760
51344703 Mettler Toledo® 51344703 Calcium Combined Ion-selective electrode
$1,235.40
Ca2+ comb Ca2+ 1.2 m; BNC 5 · 10-7 to 1 mol/L
0.02 to 40100 mg/L
0 to 40 oC 2.5 to 11 Polymer Ion Electrolyte A Calcium 51344761
51344706 Mettler Toledo® 51344706 Chloride Combined Ion-selective electrode
$1,152.75
Cl- comb Cl- 1.2 m; BNC 5 · 10-5 to 1 mol/L
1.8 to 35500 mg/L
0 to 80 oC 2 to 12 Solid state Ion Electrolyte B Chloride 51344760
51344709 Mettler Toledo® 51344709 Cyanide Combined Ion-selective electrode
$1,235.40
CN- comb CN- 1.2 m; BNC 8 · 10-6 to 10-2 mol/L
0.2 to 260 mg/L
0 to 80 oC 10 to 14 Solid state Ion Electrolyte B Cyanide 10 mol/L NaOH
51344712 Mettler Toledo® 51344712 Copper Combined Ion-selective electrode
$1,544.25
C22+ comb C22+ 1.2 m; BNC 10-8 to 0.1 mol/L
6.4 to 10-4 to 6354 mg/L
0 to 80 oC 2 to 12 Solid state Ion Electrolyte D Copper 51344760
51344715 Mettler Toledo® 51344715 Fluoride Combined Ion-selective electrode
$1,174.50
F comb F- 1.2 m; BNC 10-6 mol/L Saturated
0.02 mg/L saturated
0 to 80 oC 4.5 to 5.5 Solid state Ion Electrolyte A Fluoride 51344765
51344718 Mettler Toledo® 51344718 Iodide Combined Ion-selective electrode
$1,261.50
I- comb I- 1.2 m; BNC 10-81 mol/L
0.005 to 127000 mg/L
0 to 80 oC 0 to 12 Solid state Ion Electrolyte D Iodide 51344760
51344721 Mettler Toledo® 51344721 Potassium Combined Ion-selective electrode
$1,422.45
K+ comb K+ 1.2 m; BNC 10-61 mol/L
0.04 to 39000 mg/L
0 to 40 oC 2.5 to 11 Polymer Ion Electrolyte E Potassium 51344762
51344727 Mettler Toledo® 51344727 Nitrate Combined Ion-selective electrode
$1,222.35
NO3- comb 3- 1.2 m; BNC 7 to 10-61 mol/L NO3-
0.1 to 14000 mg/L NO3-
0 to 40 oC 2.5 to 11 Polymer Ion Electrolyte F Nitrate 51344763
51344730 Mettler Toledo® 51344730 Lead Combined Ion-selective electrode
$1,557.30
Pb2+ comb Pb2+ 1.2 m; BNC 10-6 to 0.1 mol/L
0.2 to 20700 mg/L
0 to 80 oC 4 to 7 Solid state Ion Electrolyte B Lead 5 mol/L NaClO4
View Cart | Specials | Contact Us | Home | Blog | Sitemap | Store Policies | Your Account | Enter Monthy Contest

For Orders, Phone toll-free 800-832-0055
All other inquiries, please phone 718-336-5900
FAX 718-627-1313
TEXT: 718-336-5900

Chat with us via WhatsApp Chat whatsapp: 718 787 8658



Scales & Equipment: Value Electronic Scales | Value Mechanical Scales | Lab / Analytical Scales | Baby Scales | Bathroom Scales | Bariatric Scales | Body Fat Monitors | Pro Body Composition Monitors | Calibration Weights | Counting Scales | Crane ScalesDeli/Food/Grocery Scales | Dynamometers | Fish/Game Scales | Floor Scales | Force Gauges | Industrial-Use Scales | Jewelry Scales | Livestock Scales"Legal for Trade" Scales | Medical Scales | Moisture Analyzers | Pallet Scales | Pocket ScalesPortable Spring Gauges | Shipping Scales  | Specialty Medical Scales | Test Stands / Force Measurement | Veterinary Scales


Manufacturers: Acculab digital scales | AND electronic scales | Best Weight mechanical scales| Detecto Physician's Scales | CAS digital scales | Chatillon/Ametek mechanical and electronic scales | DigiWeigh Economical Scales | Dillon Crane Scales, Dynamometers & Force Testing Products| Easy Weigh Legal for Trade Scales | Health O Meter Scales | Hoto Instruments | Imada Force Measurement | InScale Floor Scales | Mark-10 Force Testing | Mettler Toledo® | Minx Economical Pocket Scales | Ohaus electronic and mechanical scales | Tanita digital scales | Salter Brecknell | Sartorius Lab Balances | Seca Medical Scales | Great Gift Ideas



© 2000 2024 scalesgalore.com   All rights reserved.
Phone Myaccount cart home Home 0 clear.png