Model |
MSI-9850 |
Enclosure |
NEMA 4, IP65 milled anodized aluminum with O-ring gaskets NEMA 6, IP67 with optional long-range antenna |
Weight |
5.0 lb (2.8 kg) |
Keypad |
33 keys – 12 key alphanumeric, 4 cursor keys, 7 control keys and 10 user programmable keys. Password protected with lock feature |
Weight Display |
Six-digit, 1.2 in (30 mm) high numeric weight LED, 4 alphanumeric 0.5 in (13 mm) high data LED, 6 LED function select annunciators, 10 LED annunciators, Low battery LED indicator |
Information Display |
1.4 in x 2.6 in (36 mm x 67 mm) backlit LCD. Capable of 8 lines of 21 characters each backlight selectable On, Off or Automatic |
Power Input |
Internal AC/DC Power Supply: 85-265 VAC, 47-440 Hz/130-300 VDC. Also included an independent 7-25 VDC power input (requires optional power/switch interface cable) |
Operating Temperature |
4°F to 158°F (-20°C to 70°C) |
Radio Link |
FHSS at 2.4 GHz (up to 64 network selections) |
Radio Link Effective Range |
Typically 500 ft (150 m) indoor, 1000 ft (300 m) outdoor with standard antennas. (See optional antennas for longer range) |
Standard Antenna |
1/2 wave 2dBi, articulated |
RFI/EMI Shielding |
Exceeds NIST Handbook 44 and CE Standards |
Connectors |
RS-232, Turck compatible Pico connector |
Legal for Trage |
NTEP CC 05-077 |
Standard Features |
Scale/Channel Monitoring |
Monitors all scale channels, easy 1 button network and/or channel changes. Supports multiple display of CellScale Channels (up to 8 simultaneously) |
Calibration |
Remotely calibrates networked CellScale components |
Real-Time Clock |
Supports date/time stamping in USA and European formats |
Internal Audible Alarm |
Four unique tones available for both set and reset conditions |
Data-Logging |
Captures weighing data automatically or manually |
Barcode Scanner Interface |
Permits bar code scanners to connect directly to the MSI-9850 |
Data I/O |
Two Comm Ports, baud rates 300 to 230.4K Comm Port 1 is RS-232 and RS-422 selectable Comm Port 2 is dedicated RS-232 |
Totalizing, Statistics and Product IDs |
MSI-9850 (Function Key or Automatic). Each ID code retains full
statistics on totaled loads. Up to 32 alphanumeric product IDs
can be accessed and programmed |
Set Point Outputs |
Five relay driver outputs for 5 V - 24 V external relays. Four relay driver outputs available when the 5 V is provided by the MSI-9850 |
FIXED KEYS |
Power, Zero, Net/Gross, Tare, Alpha, Enter, Setup/Escape, Clear, Exit, 0-9 |
PROGRAMMABLE FUNCTION KEYS (10 programmable to any of the following) |
Data String Entry |
Permits barcode or keypad data string entry (up to four available) |
Total |
Totalizes loads |
Clear Last Total |
Removes last totalized load |
Show |
Next channel, last channel, next address, last address, next product ID, last product ID, totals, grand totals (Ó) or statistics |
Date and Time |
Displays current date and time |
Enter/Edit |
Product ID print strings 1 and 2 |
Send/Edit Print Strings |
Sends/edits print strings to selectable targets |
Change Units |
Change units of measure |
Setpoints |
Controls and programs CellScale setpoints Up to 32 setpoints with messaging capability |
Peak Hold |
Turns peak hold function “On” or “Off” |
Key Disabled |
Disables selected function key |
Signal Strength Test |
Tests for RF signal strength |
Display Test Characters |
Performs display test of all screens |
Data-Logging |
Enables automatic or manual data-logging |
Barcode Scanner Interface |