Model |
7824 AWT05-508645 |
7824 AWT05-508646 |
7824 AWT05-508647 |
7824 AWT05-508648 |
Capacity x Readability |
250 lb x 0.05 lb |
250 lb x 0.05 lb |
300 lb x 0.1 lb |
300 lb x 0.1 lb |
100 kg x 0.02 kg |
100 kg x 0.02 kg |
150 kg x 0.05 kg (Non approved) |
150 kg x 0.05 kg (Non approved) |
Platter Size |
12" x 14" |
24" x 24" |
24" x 24" |
24" x 24" |
Legal For Trade |
NTEP approved for use in Class III operations, CC 95-121 |
Canada Weights and Measures approval CC # AM-5099 Rev 4 |
Computer Interface |
1 x RS232 (9 way female D Type connector ), 1 x USB HID (Mini USB) or 1x USB VCP (USB-Type B)
2nd Remote display connection (RJ 45) All are positioned on the rear of the base |
Platter Type |
Stainless steel weight platter |
Stainless Steel Ball Top (9 balls) |
Stainless steel weight platter |
Stainless Steel Ball Top (9 balls) |
Display Type |
Flush fitting six digit, ½” high LCD display Optional 2nd remote six digit, ½” high LCD display housed in an extruded enclosure with a 7 foot cable, connected via RJ 45 connector on the rear of the scales base |
Number of Displays Allowed |
2 (1 standard, 1 remote display optional) |
Base Construction |
Durabridge® design with powder coated carbon steel base housing and aluminum NTEP approved analog
load cell
Duarabridge Technology helps reduces overall scale deflection when a full load is applied |
Power |
120 VAC (+10% -15%), 60 Hz, standard 3-wire ground |
Operating Environment |
Temperature: 42° F to 104° F (5° C to 40° C) Relative Humidity: 10 to 95% (non-condensing) |
Remote Display Housing Sizes |
8” x 3” x 1.5” |
Operational Keyss |
ZERO: Includes Auto Zero Tracking or Manual push button to re-establish zero reference. TEST: Runs a diagnostic test to ensure scale is fully functional and allows a real-time view of internal settings |
Units of Measure |
lb or kg (lb default)” |
Configurable Selections |
Capacity, resolution, lb or kg, filters, baud rates, protocols, auto printout, scale or post classifier Default configuration is as postal weight classifier |
Incremental Selections |
Multiples and sub-multiples of 1, 2, 5 |
Calibration |
2 point calibration process (zero and span capacity) Field calibration can be carried out by using less than full capacity weights Gravity compensation to allow the local gravity to be entered for where the scale is to be used |
Internal Resolution |
1 part in 120,000 |
Self-Diagnostics |
2 level diagnostics: front panel display test or full service diagnostics (Display, RAM,ROM, input/output & high resolution x10 division test) |
Supported Protocols |
Standard NCI default with field configurable settings of 8213, 3835, SMA, with Auto Weight Send (1200 – 19.2K baud range) Transmits weight and scale status whenever ASCII “W” is sent by a remote device) |