AND Weighing MC-1000S Precision Balance - Mass Comparators 1100g x 0.0001g |
|
Equipped with an internal mass for simplifi ed calibration of the balance. Enhanced function settings reduce errors due to drafts and vibrations. more ... |
Laboratory Equipment >
Analytical Balances >
Mass Comparators
|
|
|
|
Features
It’s not easy to find high performance, quality mass comparators that meet your budget, is it? Discover how A&D, an ISO17025 accredited calibration laboratory as well as being a weighing equipment manufacturer, can finally solve such problems for you
Enhanced stabilizing filter - High resolution balances like the MC series can respond to even the slightest environmental disturbances. For smooth and accurate mass comparison, the MC series is equipped with a special stabilizing function that copes with the effect of drafts or vibrations
Simplified calibration of the balance - Using the internal mass, you can ensure the balance accuracy with one key press when changes to the environment (such as temperature or location) take place. The internal mass value can be corrected as necessary.
Various options to minimize possible measurement errors - Even under a perfectly controlled weighing environment, there still remain errors that can arise from operation. The following tools are effective in managing such errors
Auto-centering pan (available for MC-1000/6100/10K/30K) Corrects eccentric loading automatically by bringing the mass to the center.
Precision Balances With Extended ResolutionThe MC series displays the weighing results with an extra decimal place not normally found in balances of the same capacity. Such extended resolution enables measurements of minute weight changes with heavy objects or containers. Example applications include:
Management of Liquids
- Resist inks on flat panels (glass)
- Coating materials on silicon wafers
- Moisture contents of catalysts
- Solder pastes and sealing materials on electronic parts
- Resins used for LED lenses
- Surface materials on optical lenses
- Grease in miniature bearings for hard disks
|
Management of Powders
- Medicines in pharmaceutical manufacturing – from full flow to minute flow
- Discharges (losses in weight) from feeders
- Wear volumes of metallic materials
- Cutting dust (contaminants) left on mechanical parts
- Particles caught by filters
|
Management of Gases
- Fill ration of hydrogen gas
- Gasified components
|
Production Line Weighing
- As precision check-weighing sensors with wider ranges
|
Weight:
10.00 lb
|
|
Other AND Weighing MC Precision Balances
|
Specifications
For management of masses in ASTM Class 2-7 and OIML Class F1 and below
Equipped with an internal mass for simplifi ed calibration of the balance. Enhanced function settings reduce errors due to drafts and vibrations.
Model |
Applicable mass |
0.2g |
0.5g |
1g |
2g |
5g |
10g |
20g |
50g |
100g |
200g |
500g |
1kg |
2kg |
5kg |
10kg |
20kg |
50kg |
100kg |
MC-1000 |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MC-6100 |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MC-10K |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MC-30K |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MC-100K |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model |
MC-1000 |
MC-6100 |
MC-10K |
MC-30K |
MC-100K |
Capacity x Readability |
1100g x 0.0001g (0.1 mg) |
6100g x 0.001g (1 mg) |
10.1 kg x 0.001g (1 mg) |
31 kg x 0.01 g |
101 kg x 0.1 g |
Repeatability (Standard Deviation)*1 |
0.0005 g / 1 kg |
0.004 g / 5 kg |
0.005 g / 10 kg |
0.015 g / 20 kg |
0.2 g (for 100 kg) |
0.0004 g / 500 g |
0.0015 g / 2 kg |
0.004 g / 5 kg |
0.1 g (for 60 kg) |
Linearity |
±0.002 g |
±0.02 g |
±0.03 g |
±0.2 g |
±2 g |
Sensitivity drift (10 °C to 30 °C) |
±2 ppm / °C |
±3 ppm / °C |
±6 ppm / °C |
Operating temperature |
5 °C to 40 °C (41 °F to 104 °F), 85%RH or less (no condensation) |
Display refresh rate |
5 times / second or 10 times / second |
Standard interface |
RS-232C |
Display mode |
kg, g, oz, lb, lb-oz, Troy oz, carat, momme, dwt, grain |
Internal calibration |
internal calibration |
Weighing pan (diameter) |
128 x 128 mm |
165 x 165 mm |
270 x 210 mm |
270 x 210 mm |
386 x 346 mm |
Power consumption |
Approx. 11 VA (supplied by the AC adapter) |
Approx. 15 VA (supplied by the AC adapter) |
External dimensions |
210 (W) x 317 (D) x 86 (H) mm |
300 (W) x 355 (D) x 111 (H) mm |
Platform: 346 (W) x 443 (D) x 130 (H) mm (Cable length: 3 m) |
Net weight |
Approx. 4.6 kg |
Approx. 5.1 kg |
Approx. 9.3 kg |
Approx. 18 kg |
Standard accessories |
AC adapter, Instruction manual, Glass breeze break (MC-1000/6100) or
Simple breeze break (MC-10K/30K), In-use cover, WinCT (CD-ROM) |
AC adapter, Instruction manual,In-use cover, WinCT (CD-ROM) |
|
|
|
* within the 48 continental US States
|
Optional Accessories
more info
|
AND Weighing GX-02 USB Option (Uni-directional) w/ cable for GF-Series
AND Weighing GX-02 USB Option (Uni-directional) w/ cable for GF-Series
|
|
more info
|
AND Weighing GX-04 Comparator Output with a Buzzer for GF-Series Factory Installed Only
Comparator Output with a Buzzer/RS-232C/ Current Loop Output
|
|
more info
|
AND Weighing GX-06 Analog Output/Current Loop Output for GF-Series (Factory Installed Only)
AND Weighing GX-06 Analog Output/Current Loop Output for GF-Series
|
|
more info
|
AND Weighing GX-12: Animal weighing pan (not applicable for GX/GF-200)
AND Weighing GX-12: Animal weighing pan (not applicable for GX/GF-200)
|
|
more info
|
AND Weighing GX-13: Density determination kit (for the pan size of 128 mm × 128 mm only)
AND Weighing GX-13: Density determination kit (for the pan size of 128 mm × 128 mm only)
|
|
more info
|
AND AD-8922A Remote Controller
Remote Controller for AND Weighing balances
Displays weighing data Remotely controls a weighing instrument with key operations (no access to the internal settings) Outputs weighing data to another external device such as a PC or printer via the RS-232C connection Optional BCD, comparator, and analog outputs available Can be panel-mounted
|
|
more info
|
AND Weighing GX-04K Comparator output with a buzzer/RS-232C/Current loop output for MC-10K/30K Factory Installed Only
AND Weighing GX-04K Comparator output with a buzzer/RS-232C/Current loop output for MC-10K/30K Factory Installed Only
|
|
more info
|
AND Weighing GX-06K Analog Output/Current Loop Output for MC-10K/30K (Factory Installed Only)
AND Weighing GX-06K Analog Output/Current Loop Output for MC-10K/30K (Factory Installed Only)
|
|
more info
|
AND Weighing GX-07K Waterproof RS-232C cable (5 m) for MC-10K/30K
AND Weighing GX-07K Waterproof RS-232C cable (5 m) for MC-10K/30K
|
|
more info
|
AND Weighing GX-15 Carrying Case for MC-10K/30K
AND Weighing GX-15 Carrying Case for MC-10K/30K
|
|
more info
|
AND AD-1682 Rechargeable Battery Pack
Rechargeable Battery Pack for AND Weighing balances
|
|
more info
|
AND Weighing AD-1684 -Electrostatic Field Meter
Features |
Range |
0 ~ ±1.49kV (low range) |
±1.0kV ~ ±20.0kV (high range) |
0 ~ ±200V (ion balance measuring range) |
Power supply |
9V battery (006P) × 1 |
30 hours (max.) Size --123mm(L) × 73mm(W) × 25mm(H)Weight |
Approx. 170g |
Size |
123mm(L) × 73mm(W) × 25mm(H)Weight |
Approx. 170g |
|
|
more info
|
AND Weighing- AD-1688 -Weighing Data Logger
AD-1688 |
Specifications |
Application devices |
Balances and scales manufactured by A&D with an RS-232C connector |
Memory size |
Approx. 5,000 data sets in the standard format (15 characters in 1 data set) can be stored |
Clock error |
±1 minute / month |
Applicable OS |
Windows 2000 / XP / Vista |
Dedicated power supply |
Not required. Power is supplied by the weighing instrument or PC. |
Operating environment |
50°F - 86°F (5°C - 40°C ), 85%RH or less (no condensation) |
Dimensions |
Approx. 2.1 oz (60 g) |
Weight |
Approx. 2.1 oz (60 g) |
|
|
more info
|
AND Weighing AD-1689 Calibration weight tweezers, pack of 5
With a length of 210 mm, the tweezers allow a weight to be placed in a weighing pan without having to put a hand inside the chamber. This prevents convection flow that is normally attributed to heat coming from the hand. |
Each tweezer is made from austenitic stainless steel (SUS304), therefore heat from the hand is unlikely to be transmitted to the weight via the tweezers. This is especially effective for the precise measurements required of analytical balances.
|
Tips of the tweezers are covered in resin to prevent the weight from slipping. The hilt is also covered with resin for easy gripping. |
|
|
more info
|
AND Weighing AD-8127 Compact Multi-Function Printer
Features
- Easy setting and operation with a numeric keypad and
LCD display
- Built-in calendar and clock for printing date and time
at any time
- Sends re-zero and weighing data request commands to
the balance/scale
- Clear and visible dot matrix printing, which also enables long-term preservation of the
printed records
- Compact and lightweight for portability and installation anywhere
- Interval printing mode for printing weighing data at set intervals
- Chart printing mode for printing time-series variations of weighing data
- Dump printing mode to receive and print GLP/GMP/GCP/ISO compliant output from
the balance/scale
- Performs and prints the results of statistical calculation including standard deviation
- Prints an ID number set for the printer at any time
- Two types of RS-232C cables (D-Sub 25P and D-Sub 9P) provided as standard to
connect to balances/scales with different interfaces*
- Receives a print, paper feed, print statistical calculation results, print total, re-zero, or
weighing data request command from the optional foot switch (AX-SW128)
Character specifications |
7 × 9 dots, 1.6 (W) × 3.2 (H) mm |
Printing speed |
Approx. 1.6 lines/second |
Paper feeding speed |
Approx. 4 lines/second |
Number of characters printed |
24 characters/line |
Printer paper width |
57.5 mm |
Operating environment |
0 to 40 °C/32 to 104 °F, 35 to 85%RH (no condensation) |
Storage environment |
-20 to 60 °C/-4 to 140 °F, 10 to 90%RH (no condensation) |
Interface |
RS-232C (D-Sub 9P, male) / Current loop (DIN) |
Power supply |
AC adapter |
Size / weight |
174 (W) × 141 (D) × 87 (H) mm / approx. 500 g |
Standard accessories |
Ink ribbon (1 pc), plain printer paper (1 roll), AC adapter, AC adapter label, instruction manual, two RS-232C cables (D-Sub 25P and D-Sub 9P)* |
|
|
more info
|
AND SW-128 Foot Switch
Foot switch for AND Weighing balances
|
|
more info
|
AND Weighing KO:WW9-25: RS-232C Cable, 25 pin male to 9 pin female for AD-1192
AND Weighing ,KO:WW9-25:, RS-232C Cable,, 25 pin male to 9 pin female RS-232C Cable, 25 pin male to 9 pin female (for BM, EJ, EKi/EWi, FCi/FCSi, FXi(WP)/ FZi(WP), GH, JM) RS-232C Cable, 25 pin male to 9 pin female (for BM, EJ, EKi/EWi, FCi/FCSi, FXi(WP)/ FZi(WP), GH, JM)
|
|
more info
|
AND Weighing TB:648 120V/220V AC Adapter
Compatible with the following units: Phoenix GH Series, Gemini GR Series, Galaxy HR Series, Orion HR Series, GF Series, GX Series, FZ Series, FX Series, BM Series, MC Series, AD Pipette Series
|
|
more info
|
A&D Weighing AX-USB-2920-25P USB to 25 pin RS-232 Converter
A&D Weighing AX-USB-2920-25P USB to 25 pin RS-232 Converter
|
|
|
|
|
|
|