AND Weighing FX-3000iN Legal For Trade Class II Precision Balance,3200 x 0.01 g
A&D’s FX-i Series entry level precision balance is a full-featured 0.01g to 1mg resolution balance at a very affordable price. The patented Compact Super Hybrid Sensor is at the heart of this unit and provides fast, one-second weighing response time more ...
A&D’s FX-i Series entry level precision balance is a full-featured 0.01g to 1mg resolution balance at a very affordable price. The patented Compact Super Hybrid Sensor is at the heart of this unit and provides fast, one-second weighing response time.
The FX-i also contains a specially designed internal shock absorber that offers protection from the adverse effects of vertical or transverse overloading. Legal-for-trade models (NTEP and Measurement Canada) are also available.
Statistical Calculation Function
The statistical values Sum, Maximum, Minimum,Range, Standard Deviation, Number of Data,and Coeffi cient of Variation can be displayedor output.
Comparator Function
Easy to compare weighing results by setting HI limit and LO limit to display HI,OK,LO indicator.
ACAI – Automatic Counting Accuracy Improvement
This counting function recalculates the average weight each time a sample is added to eliminate errors caused by variations in unit weight.
Percent Mode Function
A sample can be registered as 100% and the weight of another sample can be compared as a percentage
Animal Weighing Function
The HOLD function enables freezing of weighing data for animal weighing applications and an ANIMAL indicator appears on the display.
Underhook
The underhook allows for measurement of magnetic materials and density measurements in air and water
Standard RS-232C Interface
Incorporates bi-directional communication with a PC, printer or other peripheral devices.
GLP/GMP/GCP/ISO Compliant
In accordance with GLP and LIMS regulations the balance ID number and calibration data can be printed out using A&D’s AD-8121B or a PC.
Auto Power OFF Function
The display switches OFF automatically when the balance is inactive for 10 minutes as a power-saving tool.
Built-in Rechargeable Battery (FXi-09)
An optional Ni-MH rechargeable battery pack can be fitted into the FX-i series for use without AC power and for mobile applications (10 hours charging time for 8 hours operation).
Weight:10.00 lb
Specifications
Model
FX-120i
FX-200i
FX-300i
FX-1200i
FX-2000i
FX-3000i
Capacity X Readability
122 g x 0.001g
220 g x 0.001g
320 g x 0.001g
1220 g x 0.01g
2200 g x 0.01g
3200 g x 0.01g
4.30 x 0.00005 oz
7.76 x 0.00005 oz
11.28 x 0.00005 oz
43.0 x 0.0005 oz
77.6 x 0.0005 oz
112.8 x 0.0005 oz
0.268 x 0.000005 lb
0.485 x 0.000005 lb
0.705 x 0.000005 lb
2.68 x 0.00005 lb
4.85 x 0.00005 lb
7.05 x 0.00005 lb
0 lb, 4.30 oz x 0.01 oz
0 lb, 7.76 oz x 0.01 oz
0 lb, 11.28 oz x 0.01 oz
2 lb, 11.30 oz x 0.01 oz
4 lb, 13.60 oz x 0.01 oz
7 lb, 0.88 oz x 0.01 oz
3.92 x 0.00005 ozt
7.07 x 0.00005 ozt
10.28 x 0.00005 ozt
39.2 x 0.0005 ozt
70.7 x 0.0005 ozt
102.8 x 0.0005 ozt
610 x 0.005 ct
1100 x 0.005 ct
1600 x 0.005 ct
6100 x 0.05 ct
11000 x 0.05 ct
16000 x 0.05 ct
78.6 x 0.001 dwt
141.7 x 0.001 dwt
206.2 x 0.001 dwt
786 x 0.01 dwt
1417 x 0.01 dwt
2062 x 0.01 dwt
1882 x 0.02 GN
3395 x 0.02 GN
4938 x 0.02 GN
18827 x 0.2 GN
33951 x 0.2 GN
49383 x 0.2 GN
Legal For Trade Models
FX-120iN
FX-200iN
FX-300iN
FX-300iN-CA
FX-1200iN
FX-2000iN
FX-3000iN
NTEP Class II - NTEP CofC #08-045A2
Canada AM-5692
NTEP Class II - NTEP CofC #08-045A2
NTEP Capacity X Readability
122 g x 0.01g
220 g x 0.01g
320 g x 0.01g
1220 g x 0.1g
2200 g x 0.1g
3200 g x 0.1g
Pan Size
Ø 5.12”
Ø 5.91”
Units of Measurement
g, pcs, %, oz, lb, suit weighing environment conditions. fi tted into the FX-i series for use without AC power and
lb-oz, ozt, ct, mom, dwt, GN, tl, tol, mes and MLT
Counting Mode
Min. Unit Mass 0.001g
Min. Unit Mass 0.01g
# of Samples 5, 10, 25, 50 or 100 pieces
Percent Mode
Min. 100% Ref. Mass 0.1g
Min. 100% Ref. Mass 1.0g
Min. 100% Display 0.01%, 0.1%, 1% (depends on the reference mass stored)
Repeatability (Std. Deviation
0.001g
0.01g
Linearity
±0.002g
±0.02g
Stabilization Time (typically set at FAST)
Approx. 1 second
Sensitivity Drift
±2ppm / °C (10°C to 30°C)
Operating Temp
5°C to 40°C (41°F to 104°F), 85% RH or less (No condensation)
Display Type
Vacuum Fluorescent Display (VFD)
Display Refresh Rate
5 times / second, 10 times / second or 20 times / second
Std. Serial Interface
RS-232C Interface
Weighing Pan
130mm
150mm
External Calibration
100g 50g
200g 100g
300g 200g 100g
1000g 500g
2000g 1000g
3000g 2000g 1000g
AC Adaptor
Confirm that the adaptor type is correct for the local voltage and power receptacle
Universal Remote Display for AND Weighing balances
Connects to A&D’s balances and scales using either RS-232C or current loop
Includes an AC adapter and a communication cable that matches your instrument
Recognizes the balance/scale baud setting automatically
Large and bright VFD display
Remote Controller for AND Weighing balances
Displays weighing data Remotely controls a weighing instrument with key operations (no access to the internal settings) Outputs weighing data to another external device such as a PC or printer via the RS-232C connection Optional BCD, comparator, and analog outputs available Can be panel-mounted
The AD-1683 generates bipolar ions continuously by DC corona discharge separately from positive and negative discharge electrodes and directs the ionized air onto the charged body to eliminate static electricity. The generated ionsare well-balanced in polarity and can eliminate static electricity regardless of the polarity of the charged body
Static Electricity
Generally, insulators such as plastics are prone to be charged with static electricity when the ambient relative humidity is below 45% RH. This may affect weighing and cause a measurement error of several milligrams. The AD-1683 can eliminate static electricity very effectively
*Note: Please confirm that the AC adapter type is correct for your local voltage and receptacle type. To prevent electrical shock, insert the POWER cable into a grouding-type outlet and earth ground the grounding cable
How to install AD-1683:
Choose the installation site so that the AD-1683 can be placed beside the electronic balance and a space wide enough to place sample (10cm to 30cm from the front of the AD-1683) can be secured. Place the sample in front of the AD-1683 inside the specified area and perform static elimination. Then, weighthe sample using the electronic balance
External Dimensions
Static Eliminating Method
DC corona discharge (Bipolar)
Elimination Range
Distance:Approz. 10 cm to 30 cm from the electode. Area: 30x30 cm from the electode. (See Figure 2.)
Elimination Performance
When Charged 5kV:
Distance
10cm
20cm
30cm
50cm
Elimination Time
1 sec
4 sec
15 sec
70 sec
Ambient Temperature and Humidity Ozone Concentration
0°C to 40°C, 80% RH or less
Positive discharge pin: 0.07PPM
Negative discharge pin: 0.25PPM
(Measured at a distance of 1cm from each discharge pin.)
Power Supply
AC adapter. Please confirm that the AC adapter type is correct for your local voltage and receptacle type
AND Weighing FXi-02 Quick USB interface with cable FXi--Series
FXi-02, FXi-08 and FXi-09 cannot be used at the same time.
(Not IP65 compliant when used with FX-iWP and FZ-iWP)
AND Weighing FXi-08 Ethernet interface with WinCT-Plus software for FXi--Series
FXi-02, FXi-08 and FXi-09 cannot be used at the same time.
(Not IP65 compliant when used with FX-iWP and FZ-iWP)
AND Weighing FXi-09 Built-in rechargeable battery for FXi--Series
FXi-02, FXi-08 and FXi-09 cannot be used at the same time.
(Not IP65 compliant when used with FX-iWP and FZ-iWP)
Impact dot matrix, full range of statistical functions, interval printing with built-in clock/timer function, includes cable KO: 256A
Product Features
Impact Dot Martix Printer
A Full Range of Statistical Functions: Weight Data, Total Weight Data, Counting Data, Total Counting Data, Number of Operations, Standard Deviation, Chart, Date & TIme